RM Analyzer Help

Action > LcAddLc

Unconditional adding of the (factorized) result values of a load case to the contents of the the superposition load case

SettingDescription
Action Code of the selected Action. It is possible to switch to another action without leaving and re-entering the input function.
Action will be skipped (Option) The action will be skipped in the calculation process if the option is selected.
Input-1 > Load case name Name of the superposition load case where the result values are summed up
Input-2 > Load case name Name of the load case to be added (selection in the selection pad)
Input-3 > (Factor 1), (Factor 2), (Factor 3) Multiplication factor for the Load Case results to be added Factor  1 for primary forces, Factor 2 for secondary forces, Factor 3 for deformations

Default: 1.0 for all factors, if no value is specified If no input is made, all the factors will be set 1.0 If only Factor 1 is input, then Factor 2 and Factor 3 will be set to Factor 1 If Factor 1 and Factor 2 are input, then Factor 3 will be set to Factor 2

Output-1 > (Load case name) Name of a new load case, if the original load case (Input-1) must not be overwritten
Note: Any specified load case already existing in the load case pool, will be overwritten
Delta-T Duration of the Action (not applicable for this action)
Description Descriptive text for the selected Action (max. 80 characters)